ENDO HDF-2 series is a hemodialysis system dedicated to Hemodialysis (HD), Hemofiltration (HF), and Hemodiafiltration (HOF) treatment. These new types of systems have an elegant design, simple operation, powerful function, and more importantly, is higher dialysis treatment quality.
ENDO HDF-2 series offers the HD, HF, HOF, IUF, and sequential dilay-sis therapy options.
Support 5ml, 10ml, 20ml, 30ml, and 50ml syrings. Automatic syringe-type check.
Equip with a 10000mAh battery that can continuously operate up to 30min during power outage.
Quickly detect the liquid leakage and blood loss.
Hemodialysis Machine ENDO HDF-2
15-inche touch screen provides a perfect visual experience and an easy operation. Corrosion-resistance glass ensures the disinfectant will not cause any damage to the screen.
ENDO HDF-2 equips a large size accessory tray on the back of the screen. Acces-sories like cables, blood pressure cuff, and oximeter can be easily placed and used on it.
270-degree screen rotation satisfies different angles of demand. It is convenient for the medical staff to operate the machine and watch the screen from different directions.
Three colors sound light alarm is located on the top of the screen. It will be noticed by the medical personnel no matter on which angle.
Commonly, Hypotension and Hypertension might occur during the dialysis treatment, which will lead to multiple complications. BPM can avoid these acute complications and improve the dialysis quality.
Oxygen levels will drop 5-23% unnoticeably during dialysis. For the patient with heart and lung problems, monitoring the Sp02 can prevent the cause of unpleasant symptoms.
The cartridge system reduces the time required for both setup the machine and also the time spent clearing up once dialysis has ended. Also, it gives a more hygienic treatment and reduces the risk of contamination
Dialysate circuit dustproof cover protects the pipeline and dia lysate away from contaminating, providing more hygienic and safer dialysis treatment to the patients.
The machine equips the artery clamp and artery chamber holder to keep the treatment safe. It aviods the situation that put the patient in danger if the chamber falls down or bloodline has knotted.
CODS simplifies the maintenance and supervision involved by enabling the combined management of dialysis fluid for multiple persons, preparation of cleaning and antiseptic solutions, and delivery of these to each dialysis machine. It is a cost- effective, labor• saving, time-tested system with good microbial safety.
Combining with dialysis fluid filters, the ENDO HDF-2 series can minimize the bacteria, endotoxin, and insoluble particle to implement safe and high-efficient ultrapure dialysis treatment.
ENDO HDF-2 series provides the substitute fluid online through the double-stage DF210 dialysis fluid filters. It reduces the usage of saline and achieves safe and high-quality HOF treatment.
ENDO HDF-2 series provides the patient IC card function to document the patients' therapy data during the treatment. The individualized therapy data can be stored in the patient IC card as an electronic medical record for reviewing the previous treatment.
With two Substitute fluid pumps on ENDO HDF-2 Plus, it can implement mixed dilution (pre-dilution and post-dilution at the sametime).It combines the advantages of pre-dilution and post- dilution, improvng the dearance rate, lower the consumption of substitute fluid and anticoagulant, also reducing the cost of treatment relatively.
Normally, the dialysis fluid should keep running after the self-test and priming of the machine. The dialysis fluiid saving function will adjust the flow rate to save the cost and reduce the waste of the dialysate.
ENDO HDF-2 series provides Na+, UF, Temperature, Heparin, Bicarbonate, and Flow profiles to imple-ment personalized treatment
ENDO HDF-2 has the ability to set the isolated ultrafiltration time before it goes to the dialysis (include UF+Dispersion) treatment. After setting the I-UF timeand UF remaining time,the machine can implement the sequential dialysis to treat the patient